Finally, there is performance option that will allow one to input all the variables of the building, envelope, mechanical and lighting into a whole building simulation program to determine compliance by comparison to a baseline building. In addition to the Prescriptive Option, for Section 5 – Envelope there is a trade-off option to allow the designer to trade envelope provisions amongst each other that is, you could trade better performing glass for more glass. There are also modifiers to the prescriptive values, such as if you have an overhang over a window you are allowed to decrease the allowable fenestration solar heat gain coefficient (SHGC). For example, in Chicago for buildings with wood stud construction 16” o.c., the required wall insulation is R-13. PURPOSE The purpose of this standard is to provide minimum requirements for the energy-efficient design of buildings except low-rise residential buildings. there is a particular value and the building must comply. For brief descrip-tions and the publication dates of the addenda to 90.1-2004, see Appendix F. The primary compliance options consist of some mandatory provisions and a prescriptive type of option, i.e.
ASHRAE 90.1 2004 HOW TO
The most widely used of these is Appendix G, which deals with how to create a computer simulation of a proposed design for use with green building rating systems such as LEED. Additionally, there are sections on enforcement, definitions, alternative compliance, and climate zone maps and appendices that provide additional information on topics within the 12 chapters. The standard is organized into five major sections or chapters, each dealing with envelope, mechanical, service water heating, power, lighting systems respectively.
![ashrae 90.1 2004 ashrae 90.1 2004](https://image.slidesharecdn.com/ashrae90-170401043047/95/ashrae-901-2004-appendix-g-performance-rating-method-52-638.jpg)
There are exceptions for industrial and historic buildings, as well as for specific types of renovations particular to a specific system such as replacing light fixtures in part of a space. What that means is typically all commercial buildings and all residential buildings four stories and taller, including renovations and alterations.
ASHRAE 90.1 2004 MANUAL
Additionally ASHRAE publishes addenda, some of which may be adopted by a local jurisdiction, a users’ manual as well as manages interpretations of the standard.ĪSHRAE Standard 90.1, as stated on its cover, is applicable to all buildings except low rise residential.
ASHRAE 90.1 2004 CODE
In addition to ASHRAE Standard 90.1 there is the International Energy Conservation Code (IECC), published by the International Code Council, as well as multiple versions, or years of each. However, if adopted by a local jurisdiction, its provisions do have the force of law and as such we as design professionals are required to provide drawings and specifications that are in compliance with its provisions.
![ashrae 90.1 2004 ashrae 90.1 2004](https://d3i71xaburhd42.cloudfront.net/bb879ebda97640f45a3f3fa49d1840685932591e/85-Table4.7-1.png)
ASHRAE Standard 90.1 is an energy conservation code, not a building code.